| Previous |
|
|
|
VELOCITY
FUSE
IN-LINE |
28901-100
SERIES
FEMALE
NPTF TO
MALE NPTF CONNECTION |
|

|
| DESCRIPTION |
| - |
AN
IN-LINE VELOCITY
FUSE WITH A FEMALE
NPTF INLET AND A
MALE NPTF OUTLET
THAT PROVIDES
FULL-LINE SHUT-OFF
IN THE EVENT OF A
LINE FAILURE. |
|
| OPERATION |
| - |
A
FLOW BELOW THE
SPECIFIED LIMIT IS
ALLOWED FROM
“1” TO
“2”. |
| - |
FLOW
ABOVE THE
SPECIFIED LIMIT IS
ASSUMED TO BE A
LINE FAILURE AND
IS BLOCKED. |
| - |
FLOW
FROM “2” TO
“1” PASSES
THRU THE
CONTROLLING
ORIFICE BUT IS
UNCONTROLLED. |
| - |
CLOSING
FLOW TOLERANCE=
+15%/-0% |
|
| FEATURES |
| - |
STEEL
COMPONENTS. |
| - |
FAIL
SAFE DESIGN. |
| - |
RAPID
RESPONSE. |
|
|
|
-
SPECIFICATIONS - |
| Hydraulic
Symbol |

|
| Operating
Pressure |
3500
PSI |
|
Temperature Range |
250ºF to -40ºF |
| Reopening
Differential |
50
PSI |
|
|
ALL
DIMENSIONS IN INCHES |
|
|
-
ORDERING INFORMATION - |
|

|
|
| MODEL |
CONN.
1 |
CONN.
2 |
FLOW
RANGE |
L |
HEX. |
| 28901-102 |
1/4-18
NPTF |
1/4-18
NPTF |
0.5
– 10.0 GPM |
2.85 |
0.750 |
| 28901-103 |
3/8-18
NPTF |
3/8-18
NPTF |
0.5
– 25.0 GPM |
3.25 |
0.875 |
| 28901-104 |
1/2-14
NPTF |
1/2-14
NPTF |
2.0
– 40.0 GPM |
3.30 |
1.125 |
| 28901-106 |
3/4-14
NPTF |
3/4-14
NPTF |
2.0
– 50.0 GPM |
3.65 |
1.375 |
|
|
Click
here
for a printer-friendly page.
You will need Adobe
Acrobat Reader to view this
document.
|

|
|
 |
Vonberg
Valve, inc.
HYDRAULIC
VALVE SPECIALISTS |
3800
Industrial Avenue
Rolling Meadows, IL 60008-1085
847/ 259-3800 fax 847/259-3997 |
|
|
|
|
|
|